EZ3508sc Fluoride Ion-Selective Electrode (ISE) Standard Addition Analyser, 1 stream, 4x mA

EZ3508sc Fluoride Ion-Selective Electrode (ISE) Standard Addition Analyser, 1 stream, 4x mA
Produto n.º: EZ3508.9800140T
Preço Unitário Contacte-nos

Consistent Results in Challenging Conditions

Fluctuating water quality often compromises conventional monitoring, leading to unstable readings. The EZ3508sc uses discontinuous and standard addition modes to compensate for these matrix interferences. You get accurate, continuous fluoride data for stable process control, even as conditions change.

Reduced Maintenance and Manual Effort

Gel-filled ion selective electrodes eliminate electrolyte refilling, while automated cleaning and calibration reduce routine service needs. Discontinuous standard addition method optimises buffer and reagent consumption; lowering site visits, operating costs, and overall maintenance effort.

Seamless Integration and Connectivity

Isolated data makes process control and reporting difficult. The integrated controller platform supports standard digital communication protocols for easy connection to your existing network. You gain immediate access to critical insights, supporting faster decision-making and remote troubleshooting.

Streamlined Operation and Usability

Complex instrumentation often leads to training bottlenecks and operational errors. The unified controller interface simplifies setup and daily interaction. Operators of any experience level can easily manage the system, reducing training requirements and preventing errors during routine checks.

Conteúdos

EZ3508sc Fluoride Ion-Selective Electrode (ISE) Standard Addition Analyser, 1 stream, 4x mA, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Electrode, 1 x empty 5L Reagent Container with Fittings (for F Standard Solution) and 1 x empty 10L Reagent Container with Fittings (for Buffer Solution)

Especificações

Calibração: Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Caudal da amostra: 100 - 300 mL/min
Certificações: CE, ETL certified to UL and CSA safety standards, UKCA
Ciclo de medição: No dilution
Default: 5 minutes
Continuous: 5 minutes

Internal dilution
Default: 10 minutes
Continuous: 8 minutes
Classe de proteção: IP44
Conteúdos: EZ3508sc Fluoride Ion-Selective Electrode (ISE) Standard Addition Analyser, 1 stream, 4x mA, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Electrode, 1 x empty 5L Reagent Container with Fittings (for F Standard Solution) and 1 x empty 10L Reagent Container with Fittings (for Buffer Solution)
Demineralised water: Internal dilution option: Rinse water and Dilution water
Dimensões (A x L x P): 688 mm x 460 mm x 340 mm
Dreno: Atmospheric pressure, vented, min. Ø 32 mm
Earth connection: Earth connection Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Exactitud: Better than 2% full scale range for standard test solutions
Gama de medição: No dilution
0.2 - 10 mg/L Fˉ
0.5 - 25 mg/L Fˉ
1 -50 mg/L Fˉ
2 - 100 mg/L Fˉ

Internal dilution
10 - 500 mg/L Fˉ
20 - 1000 mg/L Fˉ
Garantia: 24 meses
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interferencias: Metal ions like aluminium [(Al)³+] > 72 mg/L, calcium [(Ca)²+] > 108 mg/L and iron [(Fe)²+/(Fe)³+] > 150 mg/L. Fats, oil, proteins, surfactants and tar.
Limite de deteção: No dilution
0.2 - 10 mg/L Fˉ: 0.2 mg/L
0.5 - 25 mg/L Fˉ: 0.5 mg/L
1 -50 mg/L Fˉ: 1 mg/L
2 - 100 mg/L Fˉ: 2 mg/L

Internal dilution
10 - 500 mg/L Fˉ: 10 mg/L
20 - 1000 mg/L Fˉ: 20 mg/L
Limpeza automática: Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Material: Hinged part: Thermoform ABS, Door: PMMA
Wall section: Galvanised steel, powder coated
Método de medição: Discontinuous measurement by combined Ion-Selective Electrode with standard addition
  Ion-Selective Electrode (standard addition)
Número de Corrientes de muestra: Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Parâmetro: Fluoride
Peso: Max. 35 kg
Potência/Energia: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Pressão da amostra: By external overflow vessel (open to atmospheric pressure)
Qualidade da amostra: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Reagent Requirements: Keep between 10 - 30 °C
Saídas analógicas: Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard 4, optional: 8
Saídas digitais: Relays: 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)

Ethernet Connections: Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP

RS485 communication: Profibus DP or Modbus RTU
Temperatura ambiente: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura da amostra: 10 - 30 °C
Validation: Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly