EZ3004 Chloride Analyser

EZ3004 Chloride Analyser
Produto n.º: EZ3004.XXXXXXXX
Preço Unitário Contacte-nos

Conteúdos

EZ3004 Chloride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Chloride Electrode and 1 x empty 2.5L Reagent Container with Fittings (for Buffer Solution)

Especificações

Alarmes: 1x malfunctioning, 4x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Calibração: Automatic, 2-point; frequency freely programmable
Caudal da amostra: 100 - 300 mL/min
Certificações: CE compliant / UL certified
Ciclo de medição: 5 minutes
Classe de proteção: Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Conteúdos: EZ3004 Chloride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Chloride Electrode and 1 x empty 2.5L Reagent Container with Fittings (for Buffer Solution)
Demineralised water: For rinsing
Dimensões (A x L x P): 690 mm x 465 mm x 330 mm
Dreno: Atmospheric pressure, vented, min. Ø 32 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Exactitud: Better than 2% full scale range for standard test solutions
Fonte de alimentação: 100 - 240 VAC, 50/60 Hz
Gama de medição: 10 ‐ 100 mg/L
  10 - 100 mg/L Cl-

Optional:
2.5 - 25 mg/L Cl-
5 - 50 mg/L Cl-
Garantia: 24 meses
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferencias: Bromide, sulphide, iodide, cyanide ions may interfere. Mercury must be absent. Ammonia and thiosulphate may interfere. Fats, oil, proteins, surfactants and tar.
Limite de deteção: 2.5 mg/L
Limpeza automática: Sim
Material: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Metodo: Ionselective
Método de medição: Discontinuous, direct measurement by combined ion-selective electrode, conform with standard methods EPA 9212 and ASTM D512-12
Modelo: EZ3004
Número de Corrientes de muestra: 1, 2, 4 or 8
Parâmetro: Chloride
Peso: 25 kg
Potência/Energia: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Pressão da amostra: By external overflow vessel
Qualidade da amostra: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Reagent Requirements: Keep between 10 - 30 °C
Saídas analógicas: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Saídas digitais: Optional: Modbus (TCP/IP, RS485)
Temperatura ambiente: 10 - 30 °C ±4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura da amostra: 10 - 30 °C
Validation: Automatic; frequency freely programmable