Calibração:
Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Caudal da amostra:
100 - 300 mL/min
Certificações:
CE, ETL certified to UL and CSA safety standards, UKCA
Ciclo de medição:
No Dilution
Default: 10 min.
Continuous: 6 min.
Internal Dilution
Default: 15 min.
Continuous: 9 min.
Classe de proteção:
IP44
Conteúdos:
EZ1032sc Phosphate Analyser, Instruction Manual, 1 x Double Bit Door key, 1 x Mounting Brackets, 1 x empty 5 Reagent Container with Fittings (for Colour Solution), and 1 x empty 2.5L Glass Reagent Container with Fittings (for Reductor Solution)
Demineralised water:
Internal dilution option: Rinse water & Dilution water
Dimensões (A x L x P):
688 mm x 460 mm x 340 mm
Dreno:
Atmospheric pressure, vented, min. Ø 32 mm
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Exactitud:
Better than 2% full scale range for standard test solutions
Gama de medição:
No Dilution
0.001 - 0.1 mg/L PO₄-P
0.003 - 0.25 mg/L PO₄-P
0.003 - 0.5 mg/L PO₄-P
0.005 - 1 mg/L PO₄-P
Internal Dilution
0.025 - 5 mg/L PO₄-P
0.050 - 10 mg/L PO₄-P
0.125 - 25 mg/L PO₄-P
0.250 - 50 mg/L PO₄-P
0.375 - 75 mg/L PO₄-P
0.500 - 100 mg/L PO₄-P
Garantia:
24 meses
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interferencias:
Arsenic (V) [(As)5+], chromium (VI) [(Cr)6+], copper (II) [(Cu)2+] > 10 mg/L, iron (III) [(Fe)3+] > 10 mg/L, sulfide [(S)2-] > 2 mg/L and vanadium [(V)5+], silica [(Si)4+] > 60 mg/L. Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Limite de deteção:
No Dilution
0.001 - 0.1 mg/L PO₄-P: 0.001 mg/L
0.003 - 0.25 mg/L PO₄-P: 0.003 mg/L
0.003 - 0.5 mg/L PO₄-P: 0.003 mg/L
0.005 - 1 mg/L PO₄-P: 0.005 mg/L
Internal Dilution
0.025 - 5 mg/L PO₄-P: 0.025 mg/L
0.050 - 10 mg/L PO₄-P: 0.05 mg/L
0.125 - 25 mg/L PO₄-P: 0.125 mg/L
0.250 - 50 mg/L PO₄-P: 0.250 mg/L
0.375 - 75 mg/L PO₄-P: 0.375 mg/L
0.500 - 100 mg/L PO₄-P: 0.500 mg/L
Limpeza automática:
Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Material:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Método de medição:
Colorimetric measurement by a vanadate blue method compliant with APHA 4500-P
Número de Corrientes de muestra:
Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Parâmetro:
Phosphate (vandate blue)
Peso:
Max. 35 kg
Potência/Energia:
100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Pressão da amostra:
By external overflow vessel (open to atmospheric pressure)
Qualidade da amostra:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Reagent Requirements:
Keep between 10 - 30 °C
Relés:
5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
Saída:
Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Saídas analógicas:
Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Saídas digitais:
Profibus DP or Modbus RTU
Temperatura ambiente:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura da amostra:
5 - 30 °C
Validation:
Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly