EZ1017 Calcium Hardness Analyser

EZ1017 Calcium Hardness Analyser
Produto n.º: EZ1017.XXXXXXXX
Preço Unitário Contacte-nos

Conteúdos

EZ1017 Calcium Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Acid, and EDTA Solution) and 1 x empty 5L Reagent Container with Fittings (for Buffer)

Especificações

Alarmes: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Calibração: Automatic, 2-point; frequency freely programmable
Caudal da amostra: 100 - 300 mL/min
Certificações: CE compliant / ETL certified
Ciclo de medição: 10 min (dilution + 5 min.)
Classe de proteção: Analyser cabinet: IP44 / Panel PC: IP65
Conteúdos: EZ1017 Calcium Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Acid, and EDTA Solution) and 1 x empty 5L Reagent Container with Fittings (for Buffer)
Demineralised water: For rinsing / dilution
Dimensões (A x L x P): 690 mm x 465 mm x 330 mm
Dreno: Atmospheric pressure, vented, min. Ø 32 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Exactitud: Better than 2% full scale range for standard test solutions
Gama de medição: 0.025 - 1 mg/L CaCO3

Optional:
0.005 - 0.5 mg/L
0.2 - 4 mg/L (with internal dilution)
0.4 - 8 mg/L (with internal dilution)
2.5 - 100 mg/L (with internal dilution)
  0.025 - 1 mg/L CaCO₃
Garantia: 24 meses
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferencias: Dissolved Copper Cu(II) > 2 mg/L, Iron Fe(II) > 20 mg/L, Manganese > 10 mg/L, Zinc > 5 mg/L, Lead > 5 mg/L, Aluminium > 5 mg/L and Tin Sn(IV) interfere. Orthophosphate precipitates Calcium at the pH of the test. Strontium and Barium give a positive interference and alkalinity in excess of 300 mg/L may cause an indistinct end point in hard waters. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Limite de deteção: ≤ 2.5 µg/L CaCO3
Limpeza automática: Sim
Material: Hinged part: Thermoform ABS, door: PMMA
Wall section: galvanised steel, powder coated
Metodo: Colorimetric
Método de medição: Colorimetric measurement at 610 nm using hydroxynaphthol blue/EDTA
Modelo: EZ1017
Número de Corrientes de muestra: 1, 2, 4, or 8
Parâmetro: Calcium Hardness
Peso: 25 kg
Potência/Energia: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Pressão da amostra: By external overflow vessel
Qualidade da amostra: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Reagent Requirements: Keep between 10 - 30 °C
Saídas analógicas: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Saídas digitais: Optional: Modbus (TCP/IP, RS485)
Temperatura ambiente: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura da amostra: 10 - 30 °C
Validation: Automatic; frequency freely programmable