Alarmes:
1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Calibração:
Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Caudal da amostra:
100 - 300 mL/min
Certificações:
CE, ETL certified to UL and CSA safety standards, UKCA
Ciclo de medição:
Default: 10 min.
Continous: 4 min.
Classe de proteção:
IP44
Conteúdos:
EZ1008sc Colour Analyser, Instruction Manual, 1 x Double Bit Door Key and 1 x Mounting Brackets
Cooling water:
Flow rate approx. 5 L/h; temperature max. 30 °C; pressure max. 0.5 bar
Demineralised water:
None
Dimensões (A x L x P):
688 mm x 460 mm x 340 mm
Dreno:
Atmospheric pressure, vented, min. Ø 32 mm
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Exactitud:
Better than 3% of full scale for 1 - 50 mg/L Pt-Co; better than 2% of full scale for all other measuring ranges.
Gama de medição:
No Dilution
1 - 50 mg/L Pt-Co
1 - 125 mg/L Pt-Co
2.5 - 250 mg/L Pt-Co
5 - 500 mg/L Pt-Co
Garantia:
24 meses
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interferencias:
Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Limite de deteção:
No Dilution
1 - 50 mg/L Pt-Co: 1 mg/L
1 - 125 mg/L Pt-Co: 1 mg/L
2.5 - 250 mg/L Pt-Co 2.5 mg/L
5 - 500 mg/L Pt-Co: 5 mg/L
Limpeza automática:
Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Material:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Método de medição:
Colorimetric measurement
Número de Corrientes de muestra:
Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Parâmetro:
Color
Peso:
Max. 35 kg
Potência/Energia:
100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Pressão da amostra:
By external overflow vessel (open to atmospheric pressure)
Qualidade da amostra:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Reagent Requirements:
Keep between 10 - 30 °C
Relés:
5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
Saída:
Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Saídas analógicas:
Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Saídas digitais:
Profibus DP or Modbus RTU
Temperatura ambiente:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura da amostra:
10 - 30 °C
Validation:
Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly